Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Emerg Infect Dis ; 30(1): 202-204, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38063079

RESUMEN

We describe hepatitis C testing of 47 (2%) of 2,266 children diagnosed with perinatal hepatitis C who were exposed during 2018-2020 in 7 jurisdictions in the United States. Expected frequency of perinatal transmission is 5.8%, indicating only one third of the cases in this cohort were reported to public health authorities.


Asunto(s)
Hepatitis C , Complicaciones Infecciosas del Embarazo , Niño , Embarazo , Femenino , Humanos , Estados Unidos/epidemiología , Transmisión Vertical de Enfermedad Infecciosa , Hepatitis C/diagnóstico , Hepatitis C/epidemiología , Complicaciones Infecciosas del Embarazo/epidemiología
2.
Transfusion ; 64(2): 200-209, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38158876

RESUMEN

BACKGROUND: Use of the National Healthcare Safety Network (NHSN) has been essential to the success of the Massachusetts Hemovigilance Program and has allowed for the timely identification of signals and trends over a defined population that correlate with national and international hemovigilance (HV) data. Here, we outline how the NHSN system is used for monitoring HV data in Massachusetts and encourage adoption of NHSN for nationwide HV surveillance. STUDY DESIGN AND METHODS: A collaboration that grew over time between local HV stakeholders and the Massachusetts Department of Public Health (MDPH) resulted in the change from a paper-based method of reporting adverse reactions and monthly transfusion activity for compliance with state requirements to replacement with statewide adoption of reporting via NHSN. RESULTS: Over 1.5 million blood products were transfused in Massachusetts between 2017 and 2021, with 3000 adverse reactions among 10 defined types reported. Using NHSN, MDPH has been able to produce numerous reports, publications, and presentations that have made previously non-obtainable HV and blood utilization data available. DISCUSSION: Although limitations to these self-reported data exist, such as lack of external validation, successful statewide implementation of NHSN for hospital blood bank reporting is possible and has benefits beyond those for regulatory oversight. It results in standardized, actionable data at both the hospital and state level, enabling inter-facility comparisons, benchmarking, and opportunities for practice improvement.


Asunto(s)
Seguridad de la Sangre , Transfusión Sanguínea , Humanos , Bancos de Sangre , Massachusetts , Atención a la Salud
4.
Open Forum Infect Dis ; 7(4): ofaa113, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32341933

RESUMEN

In 2017, state health departments notified the Centers for Disease Control and Prevention about 4 patients with shigellosis who experienced persistent illness after treatment with oral third-generation cephalosporins. Given increasing antibiotic resistance among Shigella, these cases highlight the need to evaluate the efficacy of oral cephalosporins for shigellosis.

5.
Transfusion ; 59(2): 524-533, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30427540

RESUMEN

INTRODUCTION: The National Healthcare Safety Network (NHSN) Hemovigilance Module (HM) collects data on the frequency, severity, and imputability of transfusion-associated adverse events. These events contribute to significant morbidity and mortality among transfusion patients. We report results from the first systematic assessment of eight attributes of the HM. MATERIALS AND METHODS: Standard methods were used to assess the HM. Evaluation data included training materials, system modification history, and facility survey information. A concordance analysis was performed using data from the Baystate Medical Center's (Springfield, MA) electronic transfusion reporting system. RESULTS: In 2016, system representativeness remained low, with 6% (277 of 4690) of acute care facilities across 43 jurisdictions enrolled in the HM. In 2016, 48% (2147 of 4453) and 89% (3969 of 4,453) of adverse reactions were reported within 30 and 90 days of the reaction date, respectively, compared to 21% (109 of 511) and 56% (284 of 511) in 2010, demonstrating improved reporting timeliness. Data quality from most reactions was adequate, with 10% (45 of 442) misclassified transfusion-associated circulatory overload reactions, and no incomplete transfusion-transmitted infection data reported from 2010 to 2013. When compared to the Baystate system to assess concordance, 43% (24 of 56) of NHSN-reported febrile reactions were captured in both systems (unweighted kappa value, 0.47; confidence interval, 0.33-0.61). CONCLUSION: Since the 2010 HM pilot, improvements have led to enhanced simplicity, timeliness, and strengthened data quality. The HM serves an important and unique role despite incomplete adoption nationwide. Facility efforts to track and prevent transfusion-associated adverse events through systems like the NHSN HM are a key step toward improving transfusion safety in the United States.


Asunto(s)
Seguridad de la Sangre , Transfusión Sanguínea , Atención a la Salud , Gestión de Riesgos , Reacción a la Transfusión/mortalidad , Femenino , Humanos , Masculino , Estados Unidos/epidemiología
6.
Transfusion ; 57(2): 478-483, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27774608

RESUMEN

A collaboration that grew over time between local hemovigilance stakeholders and the Massachusetts Department of Public Health (MDPH) resulted in the change from a paper-based method of reporting adverse reactions and monthly transfusion activity for regulatory compliance purposes to statewide adoption of electronic reporting via the National Healthcare Safety Network (NHSN). The NHSN is a web-based surveillance system that offers the capacity to capture transfusion-related adverse events, incidents, and monthly transfusion statistics from participating facilities. Massachusetts' hospital blood banks share the data they enter into NHSN with the MDPH to satisfy reporting requirements. Users of the NHSN Hemovigilance Module adhere to specified data entry guidelines, resulting in data that are comparable and standardized. Keys to successful statewide adoption of this reporting method include the fostering of strong partnerships with local hemovigilance champions and experts, engagement of regulatory and epidemiology divisions at the state health department, the leveraging of existing relationships with hospital NHSN administrators, and the existence of a regulatory deadline for implementation. Although limitations exist, successful implementation of statewide use of the NHSN Hemovigilance Module for hospital blood bank reporting is possible. The result is standardized, actionable data at both the hospital and state level that can facilitate interfacility comparisons, benchmarking, and opportunities for practice improvement.


Asunto(s)
Almacenamiento de Sangre , Bancos de Sangre , Seguridad de la Sangre , Transfusión Sanguínea/normas , Gestión de Riesgos , Bancos de Sangre/normas , Seguridad de la Sangre/métodos , Seguridad de la Sangre/normas , Femenino , Humanos , Masculino , Massachusetts , Gestión de Riesgos/métodos , Gestión de Riesgos/normas , Almacenamiento de Sangre/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...